HV Breakout Module Type 1.1

The CSM HV Breakout Module Type 1.1 has been specifically designed for single-phase measurement applications on a cable carryhing high voltage. It measures directly voltages up to 1.000 V and currents up to 1.400 A. Power is calculated online with 1MHz dara rate calculation.

The HV Breakout Module Type 1.1 is to be inserted into the HV power line: On one hand the cables are connected inside the module and on the other hand they are linked by adapters to the power circuit. This guarantees safety, because other HV measurement cables are not needed. In addition it is possible to insert the module easy and reusable by plug-and-play mounting.

The voltage is measured directly. Current measurement is performed by a shunt module that includes a differential amplifier, a temperature sensor and a memory chip for calibration data for automatic online temperature compensation. The output of the measurement data can be done with a maximum data rate of up to 1 MHz via the EtherCAT interface. An additional output via the CAN interface is also possible.

Key-Features:

  • Single-phase measurement of voltage (up to 1.000 V) and current (up to 1.400 A) in HV applications
  • Online power calculation with 1 MHz data rate calculation, 100% synchronous
  • Output of voltage, current and power with up to 1 MHz measurement data rate
  • Simultaneous EtherCAT and CAN bus communication

 

HV Breakout Module Type 1.1

企業

CSM Computer-Systeme-Messtechnik

CSM Computer-Systeme-Messtechnik GmbH